Target specifications with feasibility

 

1.Available Fine Pitch and CCC

 

   These values were induced by basic theory of CCC and accumulated CCC data.

   You can see how these values were induced by clicking the link and open PDF.

 

 

2. Probe Life      Maximum T/D = 4,000k

   This T/D number was obtained in actual achievement in device customer's plant in Japan using canti-lever probe of tip diameter 20μ and made of Iridium. Pad material was Aluminum.

 

3. CRes      < 0.5 Ω 

   Result of VPT Principle Confirmation Test, using Φ29μ Rhodium pin.

 

4. BCF : Balanced Contact Force

 

   VPT is like symmetrical cobra. So, BCF was estimated by data of cobra.